12kv Sf6 Insulated Load Switch on Outdoor Column

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
to see all verified strength labels (27)
  • 12kv Sf6 Insulated Load Switch on Outdoor Column
  • 12kv Sf6 Insulated Load Switch on Outdoor Column
  • 12kv Sf6 Insulated Load Switch on Outdoor Column
  • 12kv Sf6 Insulated Load Switch on Outdoor Column
  • 12kv Sf6 Insulated Load Switch on Outdoor Column
  • 12kv Sf6 Insulated Load Switch on Outdoor Column
Find Similar Products
  • Overview
  • General
  • Service environment
  • Product Parameters
  • Certifications
  • Workshop
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
PGS
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CCC
Brand
Bdn
Place of Orignal
Zhe Jiang
Phase Number
3
Mechanical Life
2000 Times
Rated Short Circuit Duration
4s
Rated Current
630/400
Insulation
Casting Insulation
Rated Voltage
12
Transport Package
Wooden Case
Specification
medium
Trademark
BDN
Origin
China
HS Code
853620
Production Capacity
500

Product Description

 

General

SF6 type outdoor high voltage hexafluoride circuit breaker (hereinafter referred to as "II III  type circuit breaker") is a new type of outdoor high voltage electrical appliance with SF6 gas as an arc extinguishing and insulating medium. The arc extinguishing chamber adopts the principle of spin arc extinguishing, and the operating mechanism is divided into manual energy storage operating mechanism (type I). (Type II) energy storage spring operating mechanism, (type III) DC electromagnetic operating mechanism three, all kinds of operating mechanism and circuit breaker body perfect combination into a whole.

Service environment

  • Ambient temperature: upper limit +40 degrees, lower limit -40 degrees

  • The altitude does not exceed 1000m

  • Wind pressure no more than 700Pa(wind speed no more than 35m/s)

  • The intensity of the earthquake does not exceed 8 degrees

  • There is no fire, explosion danger, serious pollution, chemical corrosion and violent vibration.

 

Product Parameters

Name Unit Data
Rated Voltage kV 12
Rated Insulation Level
Lightning Impulse Withstand Voltage(Full-wave Peak Value)
kV 75
Power Frequency Withstand Voltage(1 minute) 42
Rain Withstand Voltage Test 34
Reverse Phase impact Pressure 85
Insulation level under zero gauge pressure Power Frequency Withstand Voltage(1 minute) kV 30
Reverse Phase Withstand Voltage(1minute) 30
Maximum Phase Voltage (5min) 9
Rated Current   400,630
Rated Short-Circuit Breaking Current(0.25MPa,200C time) Times 16,20
Outgoing phase grounding reclosing breaking current Mpa 14,17.4
Breaking current under zero gauge voltage Mpa 400,630
Rated Operating Sequence Type I   0-180s-C/0-180s-C/O
Type II III 0-0.3s-C/0-180s-C/O
Rated Short-Circuit Closing Current(Peak Value)   40,50
Rated Withstand Current (Peak Value) 40,50
Rated Short-time Withstand Current 16,20
Rated Short-Circuit Continuous Time 4
Rated winding charging breaking current 25
Rated line charging breaking current   16
Rigid closing speed 2.0±0.2
Rigid component speed 3.6±0.2
Opening distance of dynamic and static contacts   37±2
Total travel of the conductive rod   58±2
Conducting rod overtravel   22±2
Three-phase synchronism of opening and closing   2
Main circuit resistance of each phase   130
Rated Working Pressure   0.35(200C)
Minimum Working Pressure   0.25(200C)
Annual Gas Rate   ≤0.05
Mechanical Stability Operation   10000
Water content of SF6 gas   ≤150
Weight   150
12kv Sf6 Insulated Load Switch on Outdoor Column
 

Certifications


 
12kv Sf6 Insulated Load Switch on Outdoor Column

Workshop

12kv Sf6 Insulated Load Switch on Outdoor Column
 

Packaging & Shipping

12kv Sf6 Insulated Load Switch on Outdoor Column
12kv Sf6 Insulated Load Switch on Outdoor Column12kv Sf6 Insulated Load Switch on Outdoor Column12kv Sf6 Insulated Load Switch on Outdoor Column12kv Sf6 Insulated Load Switch on Outdoor Column12kv Sf6 Insulated Load Switch on Outdoor Column12kv Sf6 Insulated Load Switch on Outdoor Column

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier