Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
to see all verified strength labels (27)
  • Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant
  • Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant
  • Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant
  • Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant
  • Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant
  • Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant
Find Similar Products
  • Overview
  • General
  • Service environment
  • Product Parameters
  • Certifications
  • Workshop
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
LW36-40.5
Arc-extinguishing Medium
SF6
Installation
Fixed
Structure
ACB
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CCC
Brand
Bdn
Place of Orignal
Zhe Jiang
Phase Number
3
Mechanical Life
2000 Times
Rated Short Circuit Duration
4s
Rated Current
630
Insulation
Casting Insulation
Rated Voltage
36.5
Transport Package
Wooden Case
Specification
medium
Trademark
BDN
Origin
China
HS Code
853620
Production Capacity
500

Product Description

 

General

Outdoor live tank self-energy HV AC SF6 circuit breaker is an outdoor three-phaseHV AC equipment used in electricity grids with altitudes of no more than 3000m, environment temperatures of no less than -40ºC, local pollution classes of no higher than Class IV, and AC 50Hz with maximum voltage of 40.5kV. It can also be used as a connection circuit breaker.

Service environment

  • Ambient air temperature -25ºC(-40ºC)~+40ºC;

  • Altitude ≤2500m(2000m);

  • Wind speed ≤34m/s;

  • Daily temperature difference ≤25ºC;

  • Sunshine intensity ≤1000W/m;

  • Seismic horizontal resistance 8 degrees: horizontal acceleration 0.2g, vertical acceleration 0.1g;

  • Ice thickness ≤10mm;

  • The degree of air pollution does not exceed Class IV in GB/T5582;

  • Outdoor installation.

  • Note: The value in brackets is the parameter when the circuit breaker air pressure is 0.33MPa.

 

Product Parameters

Name Unit Data
Rated current  A 630
Rated closing operating voltage V AC220
Rated frequency Hz 50
Rated opening operating voltage V AC220
Peak value of rated closing current KA 50
Different closing periods   2
4s Rated heat stable current KA 20
SF6 gas rated pressure (gauge pressure) Mpa 0.01
Rated energy storage motor voltage V AV220
Rated voltage KV 40.5
Rated short-circuit breaking current KA 50
Mechanical life Times 10000
Rated dynamic stable current (peak) KA 20
Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant
 

Certifications


 
Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant

Workshop

Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant
 

Packaging & Shipping

Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant
Self-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power PlantSelf-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power PlantSelf-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power PlantSelf-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power PlantSelf-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power PlantSelf-Energized Three-Phase High-Voltage Circuit Breaker Sf6 Substation Power Plant

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now